Maintenance
Coatings for all industrial environments. Maintenance products
for repairing & rebuilding plant equipment |
 |
| |

A specially formulated 100% solids epoxy grout used
to fill large holes or rebuilding severely damaged concrete
substrates. It can be applied up to 1 foot thickness in
a single pour. Chemfil can also be used as a base for
other topcoats where additional chemical resistance or
smoothness is required. |
 |
Density
(g/ml) |
Coverage
(in 3/kg) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 2.21 |
28 |
3.6:1 |
3:1 |
12,000/125 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1 |
30 |
65/18 |
250/122 |
1 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 1/4 |
24 |
72 |
SSPC-1,3,11 |
2.5-12 |

A rugged and durable 100% solids epoxy material used
for patching concrete floors, equipment pads, or containment
walls. It is supplied as a three part mix and can be built
up to a thickness of 2 inches. |
 |
Density
(g/ml) |
Coverage
(in 3/kg) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 2.02 |
20 |
2:1 |
1.8:1 |
2,000/60 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1 |
30 |
40/4 |
250/122 |
1 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 1/4 |
24 |
72 |
SSPC-1,3,11 |
2.0-14 |

A pourable three part system that is designed as a
complete self leveling floor system with excellent chemical
resistance and compressive strengths. It can be applied
at a thickness of up to two inches on horizontal surfaces.
It can also be used for producing chemical resistant equipment
pads of up to six inches in depth. |
 |
Density
(g/ml) |
Coverage
(in 3/kg) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 1.94 |
20 |
3.3:1 |
2.2:1 |
6000/60 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1 |
20 |
40/4 |
250/122 |
1 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 1/4 |
24 |
72 |
SSPC-1,3,11 |
2.0-14 |

A more chemical resistant version of the Chemcrete
Pourable used in areas where severe chemical spills are
common. |
 |
Density
(g/ml) |
Coverage
(in 3/kg) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 2.08 |
20 |
2.8:1 |
1.8:1 |
2000/60 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1 |
20 |
50/10 |
375/190 |
2 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 1/4 |
24 |
120 |
SSPC-1,3,11 |
0-5-14 |
| LINING PRODUCTS |
| Most of our 100% coating products can be used to overcoat
a properly cleaned and dry floor. However, some products,
because of their moisture tolerance, flexibility, fast
and low temperature curing capability, are better for
flooring applications than others. Listed below are some
of those materials. |
| |

A moisture tolerant, 100% solids material which can
be applied at temperatures as low as 35F. It is primarily
used to seal concrete prior to overcoating to prevent
out-gassing sealer. It can also be used as a means to
regain some structural strength in old concrete or to
prevent water penetration. |
 |
Density
(g/ml) |
Coverage
(sq ft/kg @ 40mils) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 1.08 |
40 |
9:4 |
2:1 |
5/2 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1 |
60 |
35/2 |
250/12 |
8 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 8/72 |
48 |
120 |
SSPC-1,3,11 |
3.0-12 |

A very flexible, moisture tolerant, fast curing material
which can be applied at temperatures as low as 40F with
good chemical and abrasion resistance. |
 |
Density
(g/ml) |
Coverage
(sq ft/kg @ 40mils) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 1.61 |
40 |
4:1 |
2:1 |
80/10 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1-2 |
45 |
40/4 |
375/190 |
3 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 3/24 |
24 |
120 |
SSPC-1,3,11 |
1.5-14 |

A bis-phenol F material which can be easily applied
to large concrete surfaces with or without a sealer. It
also develops its chemical resistant properties at a faster
rate than conventional novolac-based products. |
 |
Density
(g/ml) |
Coverage
(sq ft/kg @ 40mils) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 1.29 |
40 |
2.8:1 |
2:1 |
80/10 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1-2 |
45 |
40/4 |
375/190 |
7 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 6/48 |
42 |
120 |
SSPC-1,3,11 |
0.5-14 |

An extremely rugged, anti-slip floor coating system,
which is completely self contained, requiring no additional
sand or broadcasting of materials. The texture of the
surface can be changed from one suitable for shower room
floors to one which will provide slip resistance for industrial
forklift traffic, by varying the application technique. |
|
Density
(g/ml) |
Coverage
(sq ft/kg @ 40mils) |
Mix Ratio by
Weight 1 |
Mix Ratio by
Volume 1 |
Max/Min
Build/Coat (mils) |
| 1.69 |
40 |
5.6:1 |
3:1 |
150/20 |
Number of
Coats |
Working Time
(minutes) |
Minimum Application
Temp (F/C) |
Max Dry Operating
Temp (F/C) |
Dry to Touch
(hours) |
| 1 |
45 |
40/4 |
150/65 |
8 |
Recoat Time
(min/max hours) |
Functional Cure 2
(hours) |
Full Cure
(hours) |
Surface Preparation
Methods 3 |
pH Range 5 |
| 6/120 |
12 |
72 |
SSPC-1,3,11 |
|
|
|
|
|