![]() A low viscosity, long potlife coating with excellent chemical resistance in an ambient cured material. It is designed to be applied by brush, roller or with conventional airless equipment. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
45 | 1.27 | 4.2:1 | 3:1 | 10 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 80 | 60/15 | 350/175 | 8 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
8/72 | 48 | 120 | EXP | SSPC-10 |
Application Procedure 4 |
pH Range 5 | |||
1,3 | 1.0-14 |
![]() An outstanding, versatile and easy to use 100% solids material. It can be used for circulating water pipe, sewage treatment systems, or process water tanks. It can be applied by brush, roller or with conventional spray equipment. Also available in FDA compliant versions. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
45 | 1.24 | 2.4:1 | 1.8:1 | 15 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) | Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 250 | 60/15 | 275/132 | 8 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
6/120 | 48 | 129 | EAC | SSPC-10 |
Application Procedure 4 |
pH Range 5 | |||
1,3 | 2.0-14 |
![]() A moisture tolerant version of the HPL-2510 which can be applied to dams, concrete structures, or tanks by roller or brush using divers. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
40 | 1.18 | 3:2 | 6:5 | 15 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) | Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 60 | 40/4 | 250/122 | 12 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
12/24 | 72 | 120 | SAR-UW | SSPC-6 |
Application Procedure 4 |
pH Range 5 | |||
1 | 2.5-14 |
![]() A fast curing bis-phenol F epoxy used primarily for secondary containment where excellent chemical resistance to sulfuric and other inorganic acids is required at ambient cure temperatures. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
30 | 1.29 | 2.8:1 | 2:1 | 15 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 60 | 40/4 | 375/190 | 7 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
6/48 | 42 | 120 | EXP | SSPC-10 |
Application Procedure 4 |
pH Range 5 | |||
1,4 | 0.5-14 |
![]() A high-temperature, abrasion resistant, trowel applied product for boiler skirts, incinerator outlets or anywhere requiring resistance to abrasive elements at high temperatures. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
30 | 1.81 | 2.5:1 | 2:1 | 60 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
1-2 | 125 | 65/18 | 450/232 | 3 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
3/24 | 48 | 168 | EXP-THIXSET | SSPC-5 |
Application Procedure 4 |
pH Range 5 | |||
2 | 0.5-14 |
![]() A high functionality,100% solids novolac material which can be applied by conventional airless spray equipment. It can be used in power plant outlet ducts, utility FGD systems, petrochemical and acid storage tanks, or anywhere requiring outstanding chemical resistance in an easy to apply coating system. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
45 | 1.32 | 3.6:1 | 2.5:1 | 15 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 80 | 65/18 | 375/190 | 8 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
8/72 | 72 | 168 | EXP | SSPC-10 |
Application Procedure 4 |
pH Range 5 | |||
1,3 | 0.5-14 |
![]() A high functionality, 100% solids novolac material, designed for concentrated sulfuric acid and other inorganic acid service. It can be applied by hand but is most efficiently applied over large areas by plural component airless. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
20 | 1.41 | 3:1 | 2:1 | 15 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 60 | 65/18 | 400/205 | 3 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
3/24 | 48 | 168 | EXP | SSPC-5 |
Application Procedure 4 |
pH Range 5 | |||
1,4 | 0.5-14 |
![]() A special version of the HPL-4320 designed for methylene chloride and other solvents. Requires elevated temperature cure. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
25 | 1.12 | 4.7:1 | 3.4:1 | 15 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 80 | 65/18 | 375/190 | 3 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
3/24 | 48 | 168 | EXP | SSPC-5 |
Application Procedure 4 |
pH Range 5 | |||
1,4 | 0.5-14 |
![]() A flexiblized version of the HPL-4320 used for secondary containment, ductwork or anywhere requiring better flexibility with extremely good chemical resistance. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
45 | 1.32 | 2.8:1 | 2:1 | 15 |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
2-3 | 60 | 65/18 | 350/176 | 12 |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
12/48 | 72 | 168 | EXP | SSPC-10 |
Application Procedure 4 |
pH Range 5 | |||
1,4 | 0.5-14 |
![]() A very fast reacting, polyurea material used for secondary containment or conveyor beltcoatings. Surfaces coated with this material can be put back into service in a matter of hours. This coating, must be applied using plural component spray equipment and special plural component spray guns. |
Pot Life (minutes) |
Density (g/ml) |
Mix Ratio by Weight1 |
Mix Ratio by Volume 1 |
Thick/Coat (mils) |
1 | 1.21 | 1.2:1 | 1:1 | as needed |
Number of Coats |
Max DFT (mils) |
Minimum Application Temp (F/C) |
Max Dry Operating Temp (F/C) | Dry to Touch (hours) |
1 | as needed | 20/-6 | 350/150 | 1 minute |
Recoat Time (min/max hours) |
Functional Cure 2 (hours) |
Full Cure (hours) |
Repair System |
Surface Preparation Methods 3 |
n/a | 24 | 24 | DUROTHANE | SSPC-5 |
Application Procedure 4 |
pH Range 5 | |||
4 | 3.0-10 |